Low Voltage Disconnects
And Cutouts
Designed for non critical devices that are always connected to save your main or auxiliary batteries from deep discharge.
The LVD-50 and LVD-20 families of products are built on a Solid State Design. This means zero relay clicking and associated noise, low voltage drop at full current and better accuracy.
  12V 20Amp Micro Controlled Low Voltage Disconnects
Features Include:

LVD-2012-1, LVD-2012-2 and LVD2012-3:
• Current limited for overload
• Aluminium extrusion 120(L) X 50(W) X 40(H) mm
• Encapsulated to resist moisture ingress


For More Information:
• Refer to Leaflet or feel free to contact us

LVD-2012-1,
LVD-2010-1
LVD-2012-2 and LVD2012-3
Specifications Table
Product LVD - 2012 - 1 LVD - 2012 - 2 LVD - 2012 - 3
Operating System 12 VDC 12 VDC 12 VDC
Disconnect Voltage 11.5 VDC 11.0 VDC 12.0 VDC
Capacity 20 Amp 20 Amp 20 Amp
Installation Sheets And Leaflets
LVD-2012 Range
GSL Download Button
GSL Download Button
254K PDF
617K PDF
12V/24V 50Amp Micro Controlled Low Voltage Disconnects
Features Include:

LVD-5012-1 and LVD-5024-1:
• Solid state design with accuracy better than 0.5%
• Current limited for overload
• 2 second delay for starting of vehicle and settling
   of input voltage
• 2 second delay for connecting/disconnecting for
   voltage surges/dips
• Less than 0.15V drop at full 50A load
• Low standby current drain of less than 20mA
• Aluminium extrusion 120(L) X 50(W) X 40(H) mm
• LED status indicator
• Custom cut out and cut in voltages available *
  (* Conditions Apply, call main office for more information)


For More Information:
• Refer to Leaflet or feel free to contact us

LVD-5012-1
LVD-5012-1
LVD-5024-1
Specifications Table
Product LVD-5012-1 LVD5024-1
Operating System 12 VDC 24 VDC
Disconnect Voltage 11.5 VDC 23 VDC
Capacity 50 Amp 50 Amp
Installation Sheets And Leaflets
LVD-5012-1
GSL Download Button
GSL Download Button
124K PDF
682K PDF
LVD5024-1
GSL Download Button
GSL Download Button
124K PDF
682K PDF
    Low Battery Cutouts
Features Include:

LBC-12 and LBC-12B:
• Low voltage disconnect to protect battery
• Built in LED indicator
• Spike protected
• Low current drain
• Warning indicator with audible buzzer *
• Light weight construction
  (* “B” Model Only)


For More Information:
• Refer to Leaflet or feel free to contact us

LBC-12
LBC Range
LBC-12B
Specifications Table
Product LBC-12 LBC-24
Input Voltage 10V - 14V 10V - 14V
Max Load Current 10 Amps 8 Amps
Output Connection 4 Fly Leads 4 Fly Leads
Cut In Voltage 13.4V 13.4V
Cut Out Voltage 11V 11V
Warnings - LED - LED
- Audible Buzzer
Material Type ABS Plastic ABS Plastic
Weight 19g 19g
Dimensions [LxWxH] 85mm x 67mm x 30mm 85mm x 67mm x 30mm
Installation Sheets And Leaflets
LBC-12
GSL Download Button
GSL Download Button
124K PDF
661K PDF
LBC-24
GSL Download Button
GSL Download Button
125K PDF
661K PDF